PAS5600 Wireless Integrated Vibration and Temperature Transmitter
Update Time:
Click count:
PAS5600 Wireless Integrated Vibration and Temperature Transmitter
## System Features
It is a truly fully wireless condition monitoring device requiring zero cable laying, enabling unprecedented ease of installation and maintenance for online monitoring.
### High Professionalism
Designed for petrochemical and coal mine sites with full Exia intrinsic safety explosion-proof construction. Simple installation and construction eliminate the need for bulky flameproof enclosures.
Low power consumption design with IP66 protection rating.
Professional remote diagnostic services available.
### Comprehensive Monitoring Functions
Intelligent monitoring solution integrating vibration, temperature and rotational speed measurement to monitor both steady-state and unsteady-state equipment.
Complete monitoring charts (overview diagram, time-domain waveform, spectrum analysis, trend analysis, waterfall plot, order analysis, etc.)
Detailed data lists (characteristic value list, signal statistics table, alarm list, maintenance record log, etc.)
### Advanced Data Storage
Multi-trigger data saving strategies including synchronous acquisition, rotation speed-triggered acquisition and alarm-triggered acquisition.
Intelligent data storage prevents loss of monitoring data caused by network disconnection or power failure.
### Excellent Scalability
Diverse communication options: Ethernet, optical fiber, Wi-Fi and other communication methods to adapt to various industrial sites.
## Vibration Measurement Parameters
Vibration range: ±50 g
Linearity: 1%
Frequency response: ±3 dB
Sampling frequency: 1280 Hz ~ 51.2 kHz
Analysis frequency options: 500 Hz, 1 kHz, 2 kHz, 5 kHz, 10 kHz, 20 kHz
Maximum long waveform sampling length: 2M
Configurable sampling lengths: 1K, 2K, 4K, 8K, 16K, 32K, 64K, 128K
## Temperature Measurement Parameters
Temperature measurement range: -40 ~ 125 ℃
Temperature measurement accuracy: ±1 ℃ (-40 ℃ ~ 125 ℃)
## Electrical and Structural Parameters
Power supply: Lithium thionyl chloride battery
Communication standard: 2.4 GHz IEEE 802.15.4
Transmission distance: 300 meters with no interference and unobstructed line of sight
Dimensions: 46 mm × 94 mm (diameter × height)
Contact surface diameter: 19 mm
Weight: 188 grams
Mounting thread size: Metric M6
Mounting methods: Bolt fastening or metal adhesive bonding
## Environmental Parameters
Operating temperature: -40 ~ 70 ℃
Ingress protection rating: IP67
Explosion-proof grade: ExiaIICT4 (suitable for Zone 0, Zone 1 and Zone 2 hazardous areas)